3-40 INSTALLATION Manual 0-5275
3.22 Voltage Divider for iHC Torch Height Control
For best plasma cutting performance it is necessary to maintain a constant height (standoff) above the metal while cutting. Cutting
tablesuseaTorchHeightControl(THC),alsocalledaZaxiscontrol,mostofwhichusefeedbackfromthearcvoltagetocontrol
theheight.Severalofthese,includingtheiHC,partoftheVictorTechnologiesXTCNCController,comewithaVoltageDivider
Printed Circuit Board that has to be installed inside the plasma power supply to divide the high arc voltage down to lower levels
for use with control circuits.
There is a space for mounting the V-D Board located on the upper portion of an internal vertical panel near the rear of the power
supply. Predrilled holes for mounting the iHT V-D board as well as another popular height control are provided.
CAUTION
If using another board that doesn’t align with the existing holes, remove the panel if possible before drilling. If not
possible then every precaution must be taken to keep metal filings from being deposited inside the power supply.
Install the V-D Board.
1. Locate the V-D Board which should be with the iCNC.
2. InsidethePowerSupply,locateandremovethemountingpanel’s2screwsandpanel.
3. InstalltheV-DboardstandoffsandtheV-DBoardfromtheXTiCNCthenreattachthepanelwiththe2screws,securing
the V-D board in place. If using another V-D Board, follow the instructions provided mounting it in this same location.
Space for V-D Board Ohmic clip cable port
V-D Board connection
V-D Board installed
Art # A-12079
V-D Board shown with optional wire harness for iHC controller
Control Cable.
The iHC board can be supplied with a wire harness and connector (shown in previous image), to be installed in the rear panel hole
labeled “Height Control” . The connector mates with a cable from the iHC. For other height control V-D boards a strain relief can
beinstalledinthisholeforthosecables.RefertoAppendixforwiringdiagram.
USER INPUT
HEIGHT CONTROL
F1 - 8A SB 230 VAC F2 - 8A SB 230 VAC