5-10 OPERATION Manual 0-5299
5.4 Switch Descriptions and Functions
5.4.1 Emergency Stop - Button
The Emergency Stop – Off button is used to remove power from the entire system in case of an emergency. It supplies power to the servos
and cutting controls. The power to the CNC is not removed. Motion and cutting will stop immediately when the Emergency stop is pushed in.
Turn the E-stop button clockwise and release, to apply power to the servos and cutting controls. Hold in the Emergency Stop for at least 10
seconds to allow the capacitors to discharge before releasing.
NOTE:
Before powering up we recommend that you move the Drive Switch to the off position.