5-18 OPERATION Manual 0-5299
5.6.10 IHS On/Off/Auto Switch
This is a 3 position switch controlling either the IHS or the Floating head, depending on machine options.
INITIAL HEIGHT SENSING SYSTEM
In Manual position the system activates the IHS output relay.
In Auto position the iCNC® XT activates the IHS output relay automatically
In the middle position the IHS output relay is disabled.
FLOATING HEAD SYSTEM
In Manual position the fl oating head will lower onto the material surface .
In Auto position the fl oating head will lower automatically as commanded by the controller.
In the middle (OFF) position the fl oating head will be disabled and stays in the UP position.
NOTE:
Some height controllers use the IHS signal to also activate the plasma. Control fl ow in this case: Height controller senses the
plate, torch rises to ignition height and the height controller ignites the plasma.