safety and operating instructions
7-1789200011 Pre-Welding Procedure
SECTION 7:
PRE-WELDING PROCEDURE
1. Make sure all connections have been made.
2. Turn the power source “on”.
3. Adjust the flow of the shielding gas to the desired level.
NOTE
The gun trigger on the spool gun assembly will have to be depressed to allow
gas flow.
4. If using the ESG-1 control box, adjust the run-in speed of the filler metal to the desired
value by means of the run-in speed control located on the front panel of the ESG-1.
5. Adjust the wire speed of the filler metal to the desired value by means of the wire feed
speed control located in the handle of the spool gun assembly.
6. Adjust the voltage of the power source to the desired value by means of the voltage control
located on the power source.